Go to homepage
Welcome to S-CONNECT - Components for Solutions

MOXA - ioLogik E1210

Universal I/O, 16 DIs, -10 to 60°C operating temperature
Listprice:

£168.78*

61 pieces available, delivery time: 5 - 7 working days

Icon
Prices for larger quantities please inquire.
Tel: +44 (0) 1276 819333 or e-mail: shop@s-connect.ltd.uk
Manufacturer part number: ioLogik E1210
Our article number: 11431
Questions? We will be happy to advise you! Contact form
Product information "MOXA - ioLogik E1210"
The ioLogik E1200 Series supports the most often-used protocols for retrieving I/O data, making it capable of handling a wide variety of applications. Most IT engineers use SNMP or RESTful API protocols, but OT engineers are more familiar with OT-based protocols, such as Modbus and EtherNet/IP. Moxa's Smart I/O makes it possible for both IT and OT engineers to conveniently retrieve data from the same I/O device. The ioLogik E1200 Series speaks six different protocols, including Modbus TCP, EtherNet/IP, and Moxa AOPC for OT engineers, as well as SNMP, RESTful API, and Moxa MXIO library for IT engineers. The ioLogik E1200 retrieves I/O data and converts the data to any of these protocols at the same time, allowing you to get your applications connected easily and effortlessly.

Scope of delivery: MOXA - ioLogik E1210
I/O Interfaces: Analog Input, Analog Output, Digital Input, Digital Output, Relais
Interface: Ethernet
Protocol: ModBus, TCP
Temperature Range: Standard Temperature Range
Features

Daisy-Chained Ethernet I/O Connection
This industrial Ethernet remote I/O comes with two switched Ethernet ports to allow for the free flow of information downstream to another local Ethernet device, or upstream to a control server via expandable daisy-chained Ethernet I/O arrays. Applications such as factory automation, security and surveillance systems, and tunneled connections can make use of daisy-chained Ethernet for building multidrop I/O networks over standard Ethernet cables. Many industrial automation users are familiar with multidrop as the configuration most typically used in fieldbus solutions. The daisy-chain capabilities supported by ioLogik Ethernet remote I/O units not only increase the expandability and installation possibilities for your remote I/O applications, but also lower overall costs by reducing the need for separate Ethernet switches. Daisy-chaining devices in this way will also reduce overall labor and cabling expenses.

Save Time and Wiring Costs with Peer-to-Peer Communications
In remote automation applications, the control room and sensors are often far removed, making wiring over long distances a constant challenge. With peer-to-peer networking, users may now map a pair of ioLogik Series modules so that input values will be directly transferred to output channels, greatly simplifying the wiring process and reducing wiring costs.

User-Definable Modbus TCP Addressing for Painless Upgrading of Existing Systems
For Modbus devices that are controlled and detected by fixed addresses, users need to spend a vast amount of time researching and verifying initial configurations. Users need to locate each device’s networking details, such as I/O channels or vendor-defined addresses, to enable the initial or start address of a SCADA system or PLC. Devices that support user-definable Modbus TCP addressing offer greater flexibility and easier setup. Instead of worrying about individual devices, users simply configure the function and address map to fit their needs.

Push Technology for Events
When used with MX-AOPC UA Server, devices can use active push communications when communicating changes in state and/or events to a SCADA system. Unlike a polling system, when using a push architecture for communications with a SCADA system, messages will only be delivered when changes in state or configured events occur, resulting in higher accuracy and lower amounts of data that need to be transferred.
Technical details

Input/Output Interface
Digital Input Channels: 16
Isolation: 3k VDC or 2k Vrms
Buttons: Reset button

Digital Inputs
Connector: Screw-fastened Euroblock terminal
Sensor Type: Dry contact, Wet contact (NPN or PNP)
I/O Mode: DI or event counter
Dry Contact: On: short to GND, Off: open
Wet Contact (DI to COM): On: 10 to 30 VDC, Off: 0 to 3 VDC
Counter Frequency: 250 Hz
Digital Filtering Time Interval: Software configurable
Points per COM: 8 channels

Ethernet Interface
10/100BaseT(X) Ports (RJ45 connector): 2, 1 MAC address (Ethernet bypass)
Magnetic Isolation Protection: 1.5 kV (built-in)

Ethernet Software Features
Configuration Options: Web Console (HTTP), Windows Utility (ioSearch), MCC Tool
Industrial Protocols: Modbus TCP Server (Slave), Moxa AOPC (Active Tag), MXIO Library, EtherNet/IP Adapter
Management: RESTful API, SNMPv1/v2c, SNMPv1 Trap, HTTP, DHCP Client, BOOTP, IPv4, TCP/IP, UDP
MIB: Device Settings MIB
Security: Access control list

Security Functions
Authentication: Local database

LED Interface
LED Indicators: Power, Ready, Port 1, Port 2

Modbus TCP
Functions Supported: 1, 2, 3, 4, 5, 6, 15, 16, 23
Mode: Server (Slave)
Max. No. of Client Connections: 10

EtherNet/IP
Mode: Adapter
Max. No. of Scanner Connections: 9 (for read-only), 1 (for read/write)

Power Parameters
Power Connector: Screw-fastened Euroblock terminal
No. of Power Inputs: 1
Input Voltage: 12 to 36 VDC
Power Consumption: 110 mA @ 24 VDC

Physical Characteristics
Housing: Plastic
Dimensions: 27.8 x 124 x 84 mm (1.09 x 4.88 x 3.31 in)
Weight: 200 g (0.44 lb)
Installation: DIN-rail mounting, Wall mounting
Wiring: I/O cable, 16 to 26 AWG; Power cable, 12 to 24 AWG

Environmental Limits
Operating Temperature: -10 to 60°C (14 to 140°F)
Storage Temperature (package included): -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity: 5 to 95% (non-condensing)
Altitude: 4000 m